Flow Sensor – SA5000

Description

  • Simultaneous measurement of both flow rate and temperature.
  • Designed for optimal performance with water, oils, and air.
  • Features a red/green display to identify the acceptable range quickly.
  • Equipped with switching output, analog signal, and IO-Link capabilities.
  • Allows for rotation of the process connection to achieve optimal alignment.

Technical data

  • Product Characteristics
    – Input and Output Configuration
    – Digital Outputs: 2
    – Analog Outputs: 1
  • Process Connection
    – Type: Threaded Connection
    – Thread Specification: M18 x 1.5 (Internal Thread)
  • Application
    – Suitable for Use With
    – Media: Water, Glycol Solutions, Air, Oils
    – Note on Media
    – For Low-Viscosity Oils (Viscosity ≤ 40 mm²/s at 40°C)
    – For High-Viscosity Oils (Viscosity > 40 mm²/s at 40°C)
  • Operating Conditions
    – Medium Temperature: -20°C to 90°C
    – Pressure Rating: 100 bar (10 MPa)
    – Maximum Allowable Working Pressure (for CRN Applications): 100 bar
  • Electrical Data
    – Operating Voltage: 18V to 30V DC
    – Current Consumption: Less than 100 mA
    – Protection Class: Class III
    – Reverse Polarity Protection: Yes
    – Power-On Delay Time: 10 seconds
  • Inputs / Outputs
    – Input and Output Configuration
    – Digital Outputs: 2
    – Analog Outputs: 1
    – Outputs
    – Total Number of Outputs: 2
    – Output Signal Types: Switching Signal, Analog Signal, Frequency Signal, IO-Link (Configurable)
    – Electrical Design: PNP/NPN
    – Max. Voltage Drop for Switching Output DC: 2.5V
    – Permanent Current Rating for Switching Output DC: 250 mA
    – Number of Analog Outputs: 1
    – Analog Current Output: 4-20 mA (Scalable)
    – Max. Load: 350 Ω
    – Short-Circuit Protection: Yes
    – Type of Short-Circuit Protection: Pulsed
    – Overload Protection: Yes
    – Frequency of the Output: 0-1000 Hz
  • Measuring/Setting Range
    – Probe Length: 45 mm
    – Operating Modes: Relative, Absolute Liquid, Absolute Gaseous (Absolute mode recommended for reference measurement, Factory setting: Relative)
    – Temperature Monitoring
    – Measuring Range: -20°C to 90°C
    – Resolution: 0.2°C
  • Accuracy / Deviations
    – Temperature Drift: 0.003 m/s per 1/K (< 20°C and > 70°C)
    – Temperature Gradient: 100 K/min
  • Operating Modes
    – Absolute Operating Mode
    – Repeatability: 0.05 m/s (Water, Flow Velocity: 0.05-3 m/s)
    – Relative Operating Mode
    – Accuracy: ± (7% MW + 2% MEW) (For Relative Mode, Water: 20-70°C, Inlet Length: 1.5 m, DN25 (DIN 2448), Mounting Position According to Instructions)
    – Repeatability: 0.05 m/s (Water, Flow Velocity: 0.05-3 m/s)
    – Temperature Monitoring
    – Temperature Drift: ± 0.005 K/°C
    – Accuracy: ± 0.3/±1 (Water, Flow Velocity: 0.3-3 m/s / Air, Flow Velocity: > 10 m/s)
  • Response Times
    – Response Time: 0.5 seconds (T09; Varies for different media)
  • Software / Programming
    – Parameter Setting Options: Hysteresis/Window, Normally Open/Normally Closed, Switching Logic, Current/Frequency Output, Medium Selection, Damping, Teach Function, Rotatable and Switchable Display, Standard Unit of Measurement, Process Value Color
  • Interfaces
    – Communication Interface: IO-Link
    – Transmission Type: COM2 (38.4 kBaud)
    – IO-Link Revision: 1.1
    – SDCI Standard: IEC 61131-9
    – Profiles: Smart Sensor (Process Data Variable), Device Identification, Device Diagnosis
    – SIO Mode: Yes
    – Required Master Port Type: A
    – Process Data Analog: 2
    – Process Data Binary: 2
    – Min. Process Cycle Time: 3 ms
  • Operating Conditions
    – Ambient Temperature: -40°C to 80°C
    – Storage Temperature: -40°C to 100°C
    – Protection: IP 65, IP 67
Category