Description
- Simultaneous measurement of both flow rate and temperature.
- Designed for optimal performance with water, oils, and air.
- Features a red/green display to identify the acceptable range quickly.
- Equipped with switching output, analog signal, and IO-Link capabilities.
- Allows for rotation of the process connection to achieve optimal alignment.
Technical data
- Product Characteristics
– Input and Output Configuration
– Digital Outputs: 2
– Analog Outputs: 1 - Process Connection
– Type: Threaded Connection
– Thread Specification: M18 x 1.5 (Internal Thread) - Application
– Suitable for Use With
– Media: Water, Glycol Solutions, Air, Oils
– Note on Media
– For Low-Viscosity Oils (Viscosity ≤ 40 mm²/s at 40°C)
– For High-Viscosity Oils (Viscosity > 40 mm²/s at 40°C) - Operating Conditions
– Medium Temperature: -20°C to 90°C
– Pressure Rating: 100 bar (10 MPa)
– Maximum Allowable Working Pressure (for CRN Applications): 100 bar - Electrical Data
– Operating Voltage: 18V to 30V DC
– Current Consumption: Less than 100 mA
– Protection Class: Class III
– Reverse Polarity Protection: Yes
– Power-On Delay Time: 10 seconds - Inputs / Outputs
– Input and Output Configuration
– Digital Outputs: 2
– Analog Outputs: 1
– Outputs
– Total Number of Outputs: 2
– Output Signal Types: Switching Signal, Analog Signal, Frequency Signal, IO-Link (Configurable)
– Electrical Design: PNP/NPN
– Max. Voltage Drop for Switching Output DC: 2.5V
– Permanent Current Rating for Switching Output DC: 250 mA
– Number of Analog Outputs: 1
– Analog Current Output: 4-20 mA (Scalable)
– Max. Load: 350 Ω
– Short-Circuit Protection: Yes
– Type of Short-Circuit Protection: Pulsed
– Overload Protection: Yes
– Frequency of the Output: 0-1000 Hz - Measuring/Setting Range
– Probe Length: 45 mm
– Operating Modes: Relative, Absolute Liquid, Absolute Gaseous (Absolute mode recommended for reference measurement, Factory setting: Relative)
– Temperature Monitoring
– Measuring Range: -20°C to 90°C
– Resolution: 0.2°C - Accuracy / Deviations
– Temperature Drift: 0.003 m/s per 1/K (< 20°C and > 70°C)
– Temperature Gradient: 100 K/min - Operating Modes
– Absolute Operating Mode
– Repeatability: 0.05 m/s (Water, Flow Velocity: 0.05-3 m/s)
– Relative Operating Mode
– Accuracy: ± (7% MW + 2% MEW) (For Relative Mode, Water: 20-70°C, Inlet Length: 1.5 m, DN25 (DIN 2448), Mounting Position According to Instructions)
– Repeatability: 0.05 m/s (Water, Flow Velocity: 0.05-3 m/s)
– Temperature Monitoring
– Temperature Drift: ± 0.005 K/°C
– Accuracy: ± 0.3/±1 (Water, Flow Velocity: 0.3-3 m/s / Air, Flow Velocity: > 10 m/s) - Response Times
– Response Time: 0.5 seconds (T09; Varies for different media) - Software / Programming
– Parameter Setting Options: Hysteresis/Window, Normally Open/Normally Closed, Switching Logic, Current/Frequency Output, Medium Selection, Damping, Teach Function, Rotatable and Switchable Display, Standard Unit of Measurement, Process Value Color - Interfaces
– Communication Interface: IO-Link
– Transmission Type: COM2 (38.4 kBaud)
– IO-Link Revision: 1.1
– SDCI Standard: IEC 61131-9
– Profiles: Smart Sensor (Process Data Variable), Device Identification, Device Diagnosis
– SIO Mode: Yes
– Required Master Port Type: A
– Process Data Analog: 2
– Process Data Binary: 2
– Min. Process Cycle Time: 3 ms - Operating Conditions
– Ambient Temperature: -40°C to 80°C
– Storage Temperature: -40°C to 100°C
– Protection: IP 65, IP 67