KMS502F : Graphic Display Flanged Flowmeter (25-300mm)

Description

KMS502F : Electromagnetic Flanged Flowmeters (sizes: 25mm to 300mm)

The KMS502F electromagnetic flowmeter is capable of operating over a very wide flowrange. It offers reference meter quality performance with accuracy of ± 0.5% of reading, being ideal for measurement of water and wastewater applications. With no moving parts and an obstruction-less bore, this type of flowmeter guarantees the highest level of performance, whilst maintaining a high degree of accuracy.

A self-verifying feature has been implemented in all KMS flowmeters, providing ultra-stable performance over time. All KMS flowmeters are supplied fully wired and wet tested with certificate and programmed to your specific application requirements:

  • Totals: L [ litres ] ; mL [ mililitres ]; m3 [ cubic metre ] . Total is factory programmed to be resetable or non-resetable;
  • Flowrate: L/s; L/min; L/h [ Litres per second/minute/hour]; m3 /s; m3 /min; m3 /h [ cubic metre per second/minute/hour];
  • Outputs: Pulse and 4-20mA output with 1m cable pre-wired and labeled.
  • Application examples include use in water applications (irrigation, bore water etc) and proportional speed control via the current output signal. The uses are wide and far reaching.

FEATURES

  • For all your water applications including batching.
  • Flanged connection for ANSI 150lb or Australian standard flanges.
  • Accuracy to ±0.5% ≥ 0.5 m/s with repeatability of ±0.1%.
  • Integrated verification, diagnostic function and empty pipe detection.
  • Fully wired and programmed for simple installation and start-up.
  • Power supply option: 85 – 253 VAC or 17 – 31 VDC powered.
  • Modern robust housing design with bright graphic display.
  • Programmable via 4 internal push buttons or via magnetic wand.
  • Totaliser up to 10 digits with Flowrate display and status page.
  • Hard rubber or PP liner with Hastelloy C electrodes flanged sensor.
  • Protection category: IP66 / 67 (NEMA 4/4X/6) standard.
  • Measured liquid conductivity: ≥ 5 μS/cm ( ≥20 μS/cm for water ).
  • Process temperature: -5 to 80 °C (hard rubber liner).
  • Virtually maintenance free with no moving parts.